<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://factorio-space-exploration.wiki.a0zero.ir/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=2001%3A16B8%3A2C35%3AA500%3AA8A0%3A7E0A%3A4625%3AAF6B</id>
	<title>Space Exploration - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://factorio-space-exploration.wiki.a0zero.ir/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=2001%3A16B8%3A2C35%3AA500%3AA8A0%3A7E0A%3A4625%3AAF6B"/>
	<link rel="alternate" type="text/html" href="https://factorio-space-exploration.wiki.a0zero.ir/wiki/Special:Contributions/2001:16B8:2C35:A500:A8A0:7E0A:4625:AF6B"/>
	<updated>2026-11-18T19:34:21Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.45.1</generator>
	<entry>
		<id>https://factorio-space-exploration.wiki.a0zero.ir/index.php?title=Talk:Condenser_Turbine&amp;diff=612</id>
		<title>Talk:Condenser Turbine</title>
		<link rel="alternate" type="text/html" href="https://factorio-space-exploration.wiki.a0zero.ir/index.php?title=Talk:Condenser_Turbine&amp;diff=612"/>
		<updated>2021-02-23T19:17:25Z</updated>

		<summary type="html">&lt;p&gt;2001:16B8:2C35:A500:A8A0:7E0A:4625:AF6B: /* Condenser output Full */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Possible additions to the page:&lt;br /&gt;
== Condenser Turbine Operation==&lt;br /&gt;
The condenser turbine takes steam as an input, and outputs water and power. It also has an internal reservoir of &amp;quot;condensing steam&amp;quot; which is an SE unique fluid.&lt;br /&gt;
&lt;br /&gt;
The condenser turbine uses 80 steam per second and returns 79.2 water per second&lt;br /&gt;
&lt;br /&gt;
=== advanced concept of operation===&lt;br /&gt;
One way to understand the functionality is to think of the condensing turbine as two buildings &lt;br /&gt;
* external building&lt;br /&gt;
**steam input: 100 per operation&lt;br /&gt;
**water output: 99 per operation&lt;br /&gt;
**condensing steam output: 65.7 per operation? &lt;br /&gt;
** 1 crafting speed? &lt;br /&gt;
* internal building &lt;br /&gt;
**condensing steam input: 60 per operation&lt;br /&gt;
**power output: up to 11.6 MW per operation&lt;br /&gt;
**1 crafting speeed&lt;br /&gt;
&lt;br /&gt;
== Condenser Turbine Orientation==&lt;br /&gt;
Picture with steam input/water output orientation&amp;lt;br&amp;gt;&lt;br /&gt;
== Condenser Turbine Tips ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* The condenser turbine can &#039;&#039;&#039;not&#039;&#039;&#039; be chained end to end as the regular turbine&lt;br /&gt;
* The condenser turbine might useful on worlds without natural water sources&lt;br /&gt;
&lt;br /&gt;
=== Power output ===&lt;br /&gt;
The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.&lt;br /&gt;
&lt;br /&gt;
The turbine consumes a maximum of 80 steam per second. With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)&lt;br /&gt;
&lt;br /&gt;
=== Water Consumption ===&lt;br /&gt;
Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per second (verify/test?)&lt;br /&gt;
&lt;br /&gt;
The turbine consumes .1375 water per MJ produced. (verify/test?)&lt;br /&gt;
&lt;br /&gt;
The turbine consumes 137.5 water per GJ produced (verify/test?)&lt;br /&gt;
&lt;br /&gt;
== Troubleshooting turbine states ==&lt;br /&gt;
Consider the following error states. The tool tips description applies to the &amp;quot;two building&amp;quot; operation theory&lt;br /&gt;
==== Steam input low ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: Condensing turbine is not receiving enough steam to operate&lt;br /&gt;
&lt;br /&gt;
==== Water output full ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: Condensing turbine does not have enough room to output water&lt;br /&gt;
&lt;br /&gt;
==== Condenser output Full ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: external building cannot generate 65 condensing steam to put into the internal building &lt;br /&gt;
** The turbine is fully operational!&lt;br /&gt;
**  if power demand increases the turbine can provide more power&lt;br /&gt;
** if the turbine is creating maximum power, this error will still occur intermittently because the input/output quantities do not match between the external and internal building&lt;/div&gt;</summary>
		<author><name>2001:16B8:2C35:A500:A8A0:7E0A:4625:AF6B</name></author>
	</entry>
	<entry>
		<id>https://factorio-space-exploration.wiki.a0zero.ir/index.php?title=Talk:Condenser_Turbine&amp;diff=611</id>
		<title>Talk:Condenser Turbine</title>
		<link rel="alternate" type="text/html" href="https://factorio-space-exploration.wiki.a0zero.ir/index.php?title=Talk:Condenser_Turbine&amp;diff=611"/>
		<updated>2021-02-23T19:13:05Z</updated>

		<summary type="html">&lt;p&gt;2001:16B8:2C35:A500:A8A0:7E0A:4625:AF6B: /* Condenser Turbine Operation */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Possible additions to the page:&lt;br /&gt;
== Condenser Turbine Operation==&lt;br /&gt;
The condenser turbine takes steam as an input, and outputs water and power. It also has an internal reservoir of &amp;quot;condensing steam&amp;quot; which is an SE unique fluid.&lt;br /&gt;
&lt;br /&gt;
The condenser turbine uses 80 steam per second and returns 79.2 water per second&lt;br /&gt;
&lt;br /&gt;
=== advanced concept of operation===&lt;br /&gt;
One way to understand the functionality is to think of the condensing turbine as two buildings &lt;br /&gt;
* external building&lt;br /&gt;
**steam input: 100 per operation&lt;br /&gt;
**water output: 99 per operation&lt;br /&gt;
**condensing steam output: 65.7 per operation? &lt;br /&gt;
** 1 crafting speed? &lt;br /&gt;
* internal building &lt;br /&gt;
**condensing steam input: 60 per operation&lt;br /&gt;
**power output: up to 11.6 MW per operation&lt;br /&gt;
**1 crafting speeed&lt;br /&gt;
&lt;br /&gt;
== Condenser Turbine Orientation==&lt;br /&gt;
Picture with steam input/water output orientation&amp;lt;br&amp;gt;&lt;br /&gt;
== Condenser Turbine Tips ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* The condenser turbine can &#039;&#039;&#039;not&#039;&#039;&#039; be chained end to end as the regular turbine&lt;br /&gt;
* The condenser turbine might useful on worlds without natural water sources&lt;br /&gt;
&lt;br /&gt;
=== Power output ===&lt;br /&gt;
The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.&lt;br /&gt;
&lt;br /&gt;
The turbine consumes a maximum of 80 steam per second. With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)&lt;br /&gt;
&lt;br /&gt;
=== Water Consumption ===&lt;br /&gt;
Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per second (verify/test?)&lt;br /&gt;
&lt;br /&gt;
The turbine consumes .1375 water per MJ produced. (verify/test?)&lt;br /&gt;
&lt;br /&gt;
The turbine consumes 137.5 water per GJ produced (verify/test?)&lt;br /&gt;
&lt;br /&gt;
== Troubleshooting turbine states ==&lt;br /&gt;
Consider the following error states. The tool tips description applies to the &amp;quot;two building&amp;quot; operation theory&lt;br /&gt;
==== Steam input low ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: Condensing turbine is not receiving enough steam to operate&lt;br /&gt;
&lt;br /&gt;
==== Water output full ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: Condensing turbine does not have enough room to output water&lt;br /&gt;
&lt;br /&gt;
==== Condenser output Full ====&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Example.jpg|&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Error explanation: building 1 cannot generate 65 condensing steam to put inside building 2&lt;br /&gt;
** The turbine is fully operational!&lt;br /&gt;
**  if power demand increases the turbine can provide more power&lt;/div&gt;</summary>
		<author><name>2001:16B8:2C35:A500:A8A0:7E0A:4625:AF6B</name></author>
	</entry>
</feed>