|
|
| (3 intermediate revisions by 3 users not shown) |
| Line 1: |
Line 1: |
| == Technology==
| | #REDIRECT [[Condenser turbine]] |
| The Condenser Turbine is a structure unlocked by the technology ''Condenser Turbine''. It is described as having "75% the efficiency of a steam turbine but 99% of the steam used is returned as water."
| |
| | |
| The Condenser Turbine technology also unlocks a recipe for condensing steam to water in a chemical plant, allowing you to save 165 degrees C waste steam produced by some recipes (however generating no power).
| |
| | |
| == Condenser Turbine Operation==
| |
| The condenser turbine takes 100 to 999 degrees C steam as an input, and outputs water and power. It also has an internal reservoir of "condensing steam" which is an SE unique fluid.
| |
| | |
| The condenser turbine uses 80 steam per second and returns 79.2 water per second
| |
| | |
| | |
| === Condenser Turbine Orientation===
| |
| [[File:Turbine orientation.png |thumb|none]] | |
| | |
| ===Condenser Turbine Tips ===
| |
| * Multiple condenser turbines can '''not''' be chained end to end as the regular turbine
| |
| * The condenser turbine might useful on worlds without natural water sources
| |
| | |
| ==== Power output ====
| |
| The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.
| |
| | |
| With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)
| |
| | |
| More power discussion at the [[Guide:_Power|Power Guide]]
| |
| | |
| ==== Water Consumption ====
| |
| Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per operation (need to verify/test?).
| |
| | |
| In a closed loop, water limited setup, this water is removed permanently and must be replaced for continuous operation.
| |
| | |
| The turbine removes .1375 water per MJ produced.
| |
| | |
| The turbine consumes 137.5 water per GJ produced
| |
| | |
| == Advanced concept of operation - Two Buildings ==
| |
| One way to understand the function and tool tip of the turbine is to view it as two buildings combined
| |
| * External ''visible'' building
| |
| **steam input: 100 per operation
| |
| **water output: 99 per operation
| |
| **condensing steam output: 65.7 per operation?
| |
| ** 1 crafting speed (?)
| |
| * Internal ''hidden'' building
| |
| **condensing steam input: 60 per operation
| |
| **power output: up to 5.8 MW per operation
| |
| **1 crafting speed (?)
| |
| <br>
| |
| The two buildings are throughput limited such that 80 steam per second is consumed at maximum power demand
| |
| | |
| == Troubleshooting turbine states ==
| |
| Consider the following error states. The tool tips description applies to the "two building" operation theory
| |
| ==== Steam input low ====
| |
| [[File:CT steam input low.png|frame|none]]
| |
| | |
| * Error explanation: Condensing turbine is not receiving enough steam to operate
| |
| | |
| ==== Water output full ====
| |
| [[File:CTurbine water output full.png|frame|none]]
| |
| | |
| * Error explanation: Condensing turbine does not have enough room to output water
| |
| | |
| ==== Condenser output Full ====
| |
| [[File:Condensing steam output full.png|frame|none]]
| |
| | |
| * Error explanation: external building cannot generate 65 condensing steam to put into the internal building
| |
| ** The turbine is fully operational !
| |
| ** If the error is steady state; power demand is too low. The turbine can still ramp up if demand increases.
| |
| ** If the error is intermittent; the turbine is creating maximum power but this error will still occur because the input/output quantities of the two buildings are rate limited to 80 steam/second
| |