Talk:Condenser Turbine: Difference between revisions

From Space Exploration
Jump to navigation Jump to search
imported>Thesham
imported>Thesham
Line 19: Line 19:




* The condenser turbine cannot be chained end to end like the regular turbine
* The condenser turbine can '''not''' be chained end to end as the regular turbine
* The condenser turbine is very useful on worlds without natural water sources
* The condenser turbine might useful on worlds without natural water sources


=== Power output ===
=== Power output ===
The tool tip indicates 10MW, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.
The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.


The turbine consumes a maximum of 60 steam per second. With 500C steam, the turbine generates a maximum of 4.365MW of power (5.82MW * 0.75)
The turbine consumes a maximum of 80 steam per second. With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)


=== Water Consumption ===
=== Water Consumption ===
Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .6 water per second (verify/test?)
Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per second (verify/test?)


The turbine consumes .1375 water per MJ produced. (verify/test?)
The turbine consumes .1375 water per MJ produced. (verify/test?)


The turbine consumes 137.5 water per GJ produced (verify/test?)
The turbine consumes 137.5 water per GJ produced (verify/test?)


== Troubleshooting turbine states ==
== Troubleshooting turbine states ==

Revision as of 16:34, 23 February 2021

Possible additions to the page:

Condenser Turbine Operation

The condenser turbine takes steam as an input, and outputs water and power. It also has an internal reservoir of "condensing steam" which is an SE unique fluid.

One way to understand the functionality is to think of the condensing turbine as two buildings

  • building 1 has
    • steam input
    • water output
    • condensing steam output
  • building 2 has
    • condensing steam input
    • power output
    • water output

Condenser Turbine Orientation

Picture with steam input/water output orientation

Condenser Turbine Tips

  • The condenser turbine can not be chained end to end as the regular turbine
  • The condenser turbine might useful on worlds without natural water sources

Power output

The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.

The turbine consumes a maximum of 80 steam per second. With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)

Water Consumption

Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per second (verify/test?)

The turbine consumes .1375 water per MJ produced. (verify/test?)

The turbine consumes 137.5 water per GJ produced (verify/test?)

Troubleshooting turbine states

Consider the following error states. The tool tips description applies to the "two building" operation theory

Steam input low

  • Error explanation: Condensing turbine is not receiving enough steam to operate

Water output full

  • Error explanation: Condensing turbine does not have enough room to output water

Condenser output Full

  • Error explanation: power network is not demanding enough power to consume the condensing steam
    • The turbine is fully operational!
    • if power demand increases the turbine can provide more power