Talk:Condenser Turbine: Difference between revisions
imported>Thesham |
imported>Thesham |
||
| Line 5: | Line 5: | ||
One way to understand the functionality is to think of the condensing turbine as two buildings | One way to understand the functionality is to think of the condensing turbine as two buildings | ||
* building 1 has | * building 1 has | ||
**steam input | **steam input: 100 per operation | ||
**water output | **water output: 99 per operation | ||
**condensing steam output | **condensing steam output: 65.7 per operation? | ||
** 11. operation per second? | |||
* building 2 has | * building 2 has | ||
**condensing steam input | **condensing steam input | ||
**power output | **power output | ||
** | **maximum 60 condensing steam per second? | ||
== Condenser Turbine Orientation== | == Condenser Turbine Orientation== | ||
Revision as of 18:08, 23 February 2021
Possible additions to the page:
Condenser Turbine Operation
The condenser turbine takes steam as an input, and outputs water and power. It also has an internal reservoir of "condensing steam" which is an SE unique fluid.
One way to understand the functionality is to think of the condensing turbine as two buildings
- building 1 has
- steam input: 100 per operation
- water output: 99 per operation
- condensing steam output: 65.7 per operation?
- 11. operation per second?
- building 2 has
- condensing steam input
- power output
- maximum 60 condensing steam per second?
Condenser Turbine Orientation
Picture with steam input/water output orientation
Condenser Turbine Tips
- The condenser turbine can not be chained end to end as the regular turbine
- The condenser turbine might useful on worlds without natural water sources
Power output
The tool tip indicates 10MW maximum output, but this is only possible with 1000C steam. There is no common source of 1000C steam in SE.
The turbine consumes a maximum of 80 steam per second. With 500C steam, the turbine generates a maximum of 5.82MW of power (80*.75*485*.2)
Water Consumption
Since the turbine is only 99% efficient conserving water, at maximum rate it consumes .8 water per second (verify/test?)
The turbine consumes .1375 water per MJ produced. (verify/test?)
The turbine consumes 137.5 water per GJ produced (verify/test?)
Troubleshooting turbine states
Consider the following error states. The tool tips description applies to the "two building" operation theory
Steam input low
- Error explanation: Condensing turbine is not receiving enough steam to operate
Water output full
- Error explanation: Condensing turbine does not have enough room to output water
Condenser output Full
- Error explanation: power network is not demanding enough power to consume the condensing steam
- The turbine is fully operational!
- if power demand increases the turbine can provide more power